VUVG-S18-T32U-AZT-G14-1T1L (8004874) solenoid valve

Item number:

OT-FESTO059453

pcs
Properties
Valve func­tion 2x3/2 open mono­stable
Ac­tu­a­tion type Elec­tri­cal
Valve size [mm] 18
Nor­mal nom­i­nal flow [l/min] 900
Op­er­at­ing pres­sure [bar] 1.5 to 10
Con­struc­tion set up Pis­ton pusher
Reset mode Pneu­matic spring
Per­mis­sion c CSA us (OL),
c UL us - Rec­og­nized (OL)
Pro­tec­tion cat­e­gory IP65,
IP67
Ex­haust func­tion Can be throt­tled
Seal­ing prin­ci­ple Soft
in­stal­la­tion po­si­tion ar­bi­trary
Hand as­sist ac­tu­a­tion Ratch­et­ing,
ten­ta­tive
Con­trol type pilot op­er­ated
Con­trol air sup­ply ex­ter­nal
Überdeck­ung pos­i­tive Überdeck­ung
Sig­nal con­di­tion dis­play LED
Con­trol pres­sure [bar] 1.5 to 8
Max. switch­ing fre­quency [Hz] 3
Shift­ing time off [ms] 34
Shift­ing time on [ms] 15
Power-​on time 100 %
Max. pos­i­tive test im­pulse at 0 sig­nal [µs] 1.600
Max. neg­a­tive test im­pulse for 1 sig­nal [µs] 3.000
Coil char­ac­ter­is­tic value 22 V DC: 1 W
Per­mit­ted volt­age os­cil­la­tions ± 10 %
Op­er­at­ing medium Com­pressed air to ISO 8573-​1:2010 [7:4:4]
In­for­ma­tion about op­er­at­ing and con­trol medium Oiled op­er­a­tion pos­si­ble (re­quired in fur­ther op­er­a­tions)
Os­cil­la­tion strength Trans­port use test with sever­ity level 2 to FN 942017-​4 and EN 60068-​2-6
Shock re­sis­tance Shock test with de­gree of sever­ity 2 to FN 942017-​5 and EN 60068-​2-27
Cor­ro­sion re­sis­tant class KBK 2 - mod­er­ate cor­ro­sion stress
Medium tem­per­a­ture [°C] -5 to 60
con­trol medium Com­pressed air to ISO 8573-​1:2010 [7:4:4]
am­bi­ent tem­per­a­ture [°C] -5 to 60
Prod­uct weight [g] 145
Elec­tri­cal con­nec­tion Via con­nec­tion plate
Fas­ten­ing type on ter­mi­nal strip
Pneu­matic con­nec­tion 2 G1/4
Pneu­matic con­nec­tion 4 G1/4
Ma­te­r­ial in­for­ma­tion RoHs com­pli­ant
Seals ma­te­r­ial HNBR,
NBR
Hous­ing ma­te­r­ial Alu­minium wrought alloy
Further information on OT-FESTO059453
Weight 145 g / pcs
Customs duty number 84812090
Manufacturer Festo
Documents

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available